Pressure Multiplier

TeL: (63) 404 3782 / 83     Fax: (63) 404 3785    Email: This e-mail address is being protected from spambots. You need JavaScript enabled to view it

 

An automatic device for compress air to give an outlet pressure that is double the inlet pressure.
Used to locally intensify the input pressure at points of use.

 


Note: They are not suitable as a replacement for compressors, as wear on seals and drive
pistons increases significantly during continuous operation without breaks.

 

How does it work?

Stage 1:Piston A hit 3/2 plunger and switch 5/2 Valve

Stage 2:P1 air enter Booster (A) and Drive (B) chamber

Stage 3:Exhaust Air in D (A) chamber leave

Stage 4: Pressure from Booster (A) and Drive (B) are applied to the piston A and B

Stage 5: As the piston travel, air in Booster (B) is pushed to outlet

Stage 6: The cycle alternate when the piston B hit the 3/2 valve 

 

  • The pressure booster starts automatically when the supply pressure is applied and the desired output pressure has not yet been reached.
  • When the set output pressure is reached, the pressure booster switches to energy-saving mode but restarts automatically if the pressure drops during system operation.
  • Fitted with check valve that maintains the outlet pressure when the supply of compressed air is switched off.
  • Can be mounted on any position
  • Advisable to install tank after booster to prevent fluctuating outlet pressure.
  • It is recommended to connection of a 3/2-way on-off valve on the output pressure side of the pressure booster for safe venting of the residual pressure when it is not in used.
  • Energy saving – reduce system pressure by installing pressure booster for specific application.

 

 Pressure Multiplier Brochure